Call Us

+1(956)26-99999

Double-stage compression permanent magnet variable frequency screw compressor KBseries

Double-stage compression permanent magnet variable frequency screw compressor

1. Energy-saving motor: fully enclosed permanent magnet motor, with high overload capacity, high efficiency, high power factor.


2. Efficient double-stage compression screw host: a double-stage energy efficiency compression screw host; Low speed, low noise, high displacement, durable stability and reliability.


3. Intelligent control system: control at your fingertips, easy to use, more information, more accurate and rapid fault diagnosis.

Product Details
Technical Parmeters
Catalogue Download

Double-Stage Screw Compressor Product Features


01- Energy saving motor

Fully enclosed permanent magnet motor, with high overload capacity, high efficiency, high power factor.


02- Efficient double-stage screw compressor  host

Primary energy efficiency double-stage screw compressor main engine; Low speed, low noise, high displacement, durable stability and reliability.


03- Intelligent control system

Control at your fingertips, ease of use, more information, more accurate and fast fault diagnosis.

National level two energy efficiency compression, a new internal layout


Advantages of Kapa Brand


Innovating technology and protecting the environment, Kapa listens, understands and meets customer needs.

Save the environment, ensure better services and solutions, save costs for users, and seek maximum growth space. The main purpose is to protect and save energy, stimulate the growth of economic productivity, comply with market demand, save energy and reduce environmental pollution.

With the mission of "innovation reflects value", Kapa company will continue to promote technological innovation and progress, achieve win-win results with global partners, suppliers, and employees, and create a new world of "energy saving, environmental protection, intelligence, and service". Committed to the field of aerodynamics and striving to become a world-class enterprise with world-class standards.



Permanent Magnet Screw Compressor Working Schematics


Double-stage compression permanent magnet variable frequency screw compressor


Advantages


1. High quality control(CE,SGS,ISO14001/Energy saving certificate)

2. Fast Delivery( 25-30 days for large orders)

3. Good service for pre-sale,after-sale( strong technical support and professional after-sales team)

4. Small order acceptable( Ordering quantity according to your actual needs)


Why Choose Us


Longer service life of the master machine

The rotor uses asymmetrical line running at a low speed with the support of the ball bearings and roller bearings as a result. The damage and the cost are lowered and the service life is extended. Some force is counteracted by the axial force generated by the bevel gear. So the load on the bearings of the master machine is lowered.


Permanent alignment of the electromotor and the master machine

Different from the strap compressor, the SRC series compressor can integrate the electromotor with flange, shaft coupling box-gear box. and the master machine into one in such way the master machine and the electrometer are aligned forever in the transpiration. The SRC series compressors equipped with effective and fully sealed air-cooling electromotor.


Double-stage compression permanent magnet variable frequency screw compressor


Double stage compression variable frequency screw air compressor

ModelNominal
Power
Working
Pressure
Free Air
Delivery
Weight(KG)Noise
Level
50HzKW HPbarpsim3/mincfmKGdb(A)
KB18.5-818.52581163.5123.60 63068
KB22-8223081164.2148.32 66068
KB30-8304081166.0 211.89 92068
KB37-8375081167.0 247.20 95068
KB45-8456081169.5335.49 153074
KB55-85575811612.0 423.78 158074
KB75-875100811615.0 529.72 162074
KB90-890125811618.0 635.66 210074
KB110-8110150811622.5794.58 290078
KB132-8132175811625.5900.52 305078
KB160-8160200811629.80 1052.38 385082
KB185-8185250811637.00 1306.64 400082
KB200-8200275811640.50 1430.24 530084
KB220-8220300811643.00 1518.53 570084
KB250-8250350811648.50 1712.76 630085
KB280-8280375811653.00 1871.68 700085
KB315-8315420811659.50 2101.22 780088
KB355-83554808116702472.03 865088
KB400-84005458116a#VALUE!925088
KB450-84506108116933284.26 950088


AIR COMPRESSOR MAINTENANCE

01

The air compressor shouldbe placed in a place withclean air and good ventilation.

The air compressor shouldbe placed in a place withclean air and good ventilation.

02

The air compressor should be placedhorizontally, with the belt side facingthe wall, and the maintenancespaceshould be reserved.

The air compressor should be placedhorizontally, with the belt side facingthe wall, and the maintenancespaceshould be reserved.

03

Before repairing and disassemblingthe air compressor, please tum offthe power supply and dischargethe air in the air seam.

Before repairing and disassemblingthe air compressor, please tum offthe power supply and dischargethe air in the air seam.

04

When wiring, check whether thefan rotation direction is consistentwith the arrow direction.

When wiring, check whether thefan rotation direction is consistentwith the arrow direction.

ENERGY SAVING THCHNOLOGY

Power saving of 17000o kWh per month

The starting power of the original system is 555kw,and the starting power of the new system is 320kw.

Power saving of 17000o kWh per month

Power saving of 54000 kWh per month

The starting power of the original system is 240kW,and the starting power of the new system is 132kw.

Power saving of 54000 kWh per month

Power saving of 86000 kWh per month

The starting power of the original system is 446kW,and the starting power of the new system is 325kW.

Power saving of 86000 kWh per month

Power saving of 260000 kWh per month

The starting power of the original system is 690kw,and the starting power of the new system is 420kw.

Power saving of 260000 kWh per month

Power saving of 167000 kWh per month

The starting power of the original system is 732kW,and the starting power of the new system is 50okw.

Power saving of 167000 kWh per month

Power saving of 79000 kWh per month

The starting power of the original system is 430kw,and the starting power of the new system is 320kw.

Power saving of 79000 kWh per month